最先端の技術・知識を学び、未来の医療を見つめる。

山形大学大学院医学系研究科先進的医科学専攻 重粒子線医学講座

  • 023-628-5401

活動

活動

2020年 活動

学術論文

  • Lee SH, Mizushima K, Kohno R, Iwata Y, Yonai S, Shirai T, Pan VA, Bolst D, Tran LT, Rosenfeld AB, Suzuki M, Inaniwa, T: Estimating the biological effects of helium, carbon, oxygen, and neon ion beams using 3D silicon microdosimeters. Physics in Medicine & Biology. 2020
  • 想田 光、岩井 岳夫、金井 貴幸、宮坂 友侑也、佐藤 啓、根本 建二、上野 義之、嘉山 孝正, 山形大学医学部東日本重粒子センターの建設, 加速器; 2020; 17巻; 144-150.
  • Kawashima M, Matsumura A, Souda H, Tashiro M: Simultaneous determination of the dose and linear energy transfer (LET) of carbon-ion beams using radiochromic films. Phys. Med. Biol. 2020; 65; 125002
  • Hirano Y, Kodaira S, Souda H, Osaki K, Torikoshi M: Estimations of relative biological effectiveness of secondary fragments in carbon ion irradiation of water using CR-39 plastic detector and microdosimetric kinetic model. Med. Phys. 2020; 47; 781-789.
  • Tashiro M, Souda H, Yoshida T, Sakurai H: Reconstruction of dose distributions for fine carbon-ion beams using iterative approximation toward carbon-knife. Phys. Med. Biol. 2020; 65; 225023
  • Matsumoto S, Lee SH, Imai R, Inaniwa T, Matsufuji N, Fukahori M, Kohno R, Yonai S, Okonogi N, Yamada S, Kanematsu N: Unresectable Chondrosarcomas Treated With Carbon Ion Radiotherapy: Relationship Between Dose-averaged Linear Energy Transfer and Local Recurrence. Anticancer Research, 2020;40(11):6429-35.
  • Peracchi S, James B, Pagani F, Pan V, Vohradsky J, Bolst D, Prokopovich DA, Guatelli S, Petasecca M, Lerch MLF, Lee SH, Inaniwa T, Matsufuji N, Povoli M, Kok A, Jackson M, Squire T, Rosenfeld AB, Tran LT: Radiation shielding evaluation of spacecraft walls against heavy ions using microdosimetry. IEEE Transactions on Nuclear Science. 2020:1-1.
  • Lee SH, Mizushima K, Sakata D, Kohno R, Sakama M, Iwata Y Shirai T, Pan VA, Tran LT, Rosenfeld AB, Suzuki M, Inaniwa T: Microdosimetric study for helium-ion beam using fully 3D silicon microdosimeters. In Journal of Physics: Conference Series. IOP Publishing 2020;1662(1):012022
  • Lee SH, Tansho R, Mizushima K, Furukawa T, Hara Y, Saraya Y, Saotome N, Shirai T:Effect of general ion recombination on dose measurement for high dose rate carbon-ion scanning beam. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms.2020;468:14-17.
  • Inaniwa T, Suzuki M, Lee SH, Mizushima K, Iwata Y, Kanematsu N, Shirai T:Experimental validation of stochastic microdosimetric kinetic model for multi-ion therapy treatment planning with helium-, carbon-, oxygen-, and neon-ion beams.Physics in Medicine & Biology. 65.4.2020; 65(4)045005
  • Inaniwa T, Lee SH, Mizushima K, Sakata D, Iwata Y, Kanematsu N, Shirai T:Nuclear-interaction correction for patient dose calculations in treatment planning of helium-, carbon-, oxygen-, and neon-ion beams.Physics in Medicine & Biology. 2020;65(2);025004
  • Mizushima K, Iwata Y, Muramatsu M, Lee SH, Shirai T:Experimental study on monitoring system of clinical beam purity in multiple-ion beam operation for heavy-ion radiotherapy.Review of Scientific Instruments. 2020;91(2):023309
  • Kanai T, Athena P, Furuichi W, Ching Sheng Liu, Pengbo He, Mori S: Four-dimensional carbon-ion pencil beam treatment planning comparison between robust optimization and range-adapted internal target volume for respiratory-gated liver and lung treatment. Physica Medica. 2020; 80; 277-87.
  • Nakajima Y, Kadoya N, Kanai T, Saito M, Kito S, Hashimoto S, Karasawa K, Jingu K: Evaluation of the effect of user-guided deformable image registration of thoracic images on registration accuracy among users. Medical Dosimetry. 2020; 5(3): 206-12.
  • Miyasaka Y, Kadoya N, Ito K, Umezawa R, Kubozono M, Yamamoto T, Nakajima Y, Saito M, Takayama Y, Neomoto K, Iwai T, Jingu K: Quantitative analysis of intra-fractional variation in CT-based image guided brachytherapy for cervical cancer patients. Physica Medica. 2020; 73; 164-172.
  • Ieko Y, Kadoya N, Kanai T, Nakajima Y, Arai K, Kato T, Ito K, Miyasaka Y, Takeda K, Iwai T, Nemoto K, Jingu K :The impact of 4DCT-ventilation imaging-guided proton therapy on stereotactic body radiotherapy for lung cancer. Radiological Physics and Technology. 2020; 13(3): 230-7.
  • Kadoya N, Nemoto H, Kajikawa T, Nakajima Y, Kanai T, Ieko Y, Ikeda R, Sato K, Dobashi S, Takeda K, Jingu K : Evaluation of four-dimensional cone beam computed tomography ventilation images acquired with two different linear accelerators at various gantry speeds using a deformable lung phantom. Physica Medica. 2020; 77: 75-83.

国内学会発表

  • 佐藤公彦、佐藤龍二、難波ひろみ、金井貴幸、宮坂友侑也、想田光、岩井岳夫:体表面光学式トラッキングシステムを用いた患者体表面変形の定量的解析,日本放射線腫瘍学会第33回学術大会,Web開催,2020年10月
  • 佐藤公彦、後藤直樹、平藤貴之、佐藤龍二、難波ひろみ、金井貴幸、宮坂友侑也、想田光、岩井岳夫:体表面光学式トラッキングシステムを用いた患者体表面変形解析手法の開発,第56回山形県放射線技師学術大会,Web開催,2020年11月
  • 後藤直樹、佐藤公彦、平藤貴之、佐藤龍二、難波ひろみ:フラットニングフィルターフリー(FFF)ビームの収集条件について,第56回山形県放射線技師学術大会,Web開催,2020年11月
  • 想田光、金井貴幸、宮坂友侑也、岩井岳夫、根本建二、上野義之、嘉山孝正: 山形大学医学部東日本重粒子センター建設の現状 (2), 日本加速器学会第17回年会, Web, 2020年9月
  • Souda H, Kanai T, Ieko Y, Miyasaka Y, Iwai T, Nemoto K, Yamashita H, Kayama T : Construction of East Japan Heavy Ion Center, Faculty of Medicine, Yamagata University, 日本医学物理学会第119回学術大会, Web開催, 2020年4月

国際学会発表

  • Yoshiro I, Noriyuki K, Kota A, Shohei T, Hisamichi T, Takayuki K, Kei Ichiji, Takaya Yamamoto, Hisanori Ariga, Keiichi Jingu: Evaluation of CT-Based Radiomics Features for Predicting Parameters Measured Using a Pulmonary Function Test. 2020 Joint AAPM COMP Virtual Meeting, オハイオ; 2020年 7月
  • Lee SH, Mizushima K, Sakata D, Kohno R, Sakama M, Iwata Y, Shirai T, Pan V, Tran LT, Rosenfeld AB, Suzuki M, Inaniwa T:Microdosimetric study for helium-ion beam using fully 3D silicon microdosimeters Mini- Micro- Nano- Dosimetry in conjunction with Innovation Technologies in Radiation Oncology,ウロンゴン; 2020年2月
  • Inaniwa T, Suzuki M, Lee SH, Sakata D:Stochastic microdosimetric kinetic model for hypo-fractionated multi-ion therapy. Mini- Micro- Nano- Dosimetry in conjunction with Innovation Technologies in Radiation Oncology,ウロンゴン; 2020年2月

招待講演・セミナー・シンポジウム

該当なし

書籍

  • 角谷倫之 : 詳説 非剛体レジストレーション―放射線治療領域―, 中外医学社; 2020年12月 (分担執筆者:金井貴幸、宮坂友侑也、他)

研究費

  • 科学研究費補助金 (若手研究) 「Development of Pulse Acquisition System for Accurate Beam Quality Measurement of Multi-ion Therapy and for Accurate Prediction of Biological effect」 (2020 ~ 2021、研究代表者: Lee SH)

受賞

該当なし